HOLCIM LITE
Product Description
HOLCIM LITE are non-combustible, hydrophobic insulation boards made of stone wool. The product has been designed for lightweight building partitions where no mechanical loads need to be transferred. It is ideal for both new construction and thermal renovation of existing buildings.
Image
Główne zastosowania i kluczowe właściwości
Usage
Key properties
HOLCIM LITE boards are designed for:
- thermal and acoustic insulation of pitched roofs, attic ceilings, walls, and floors in frame systems,
- filling lightweight partitions where wool does not transfer external loads,
- the first (inner) insulation layer in two-layer ventilated facade systems.
- Thermal conductivity coefficient λD: 0.035 W/mK – guarantees effective thermal protection.
- Reaction to fire: class A1 – non-flammable product
- Water repellency – the boards do not absorb water, maintaining their thermal insulation properties.
- Sound insulation – the dense, resilient structure of stone wool dampens airborne sound.
- Wide range of thicknesses: 50–300 mm – can be tailored to individual design requirements.
Deklarowane parametry
| Parametr | Symbol | Jednostka | Wartość | Metoda |
|---|---|---|---|---|
| Deklarowany współczynnik przewodzenia ciepła | λD | W/mK | 0,035 | EN 12667, EN 12939 |
| Tolerancja grubości | T | - | T2 | EN 823 |
| Stabilność wymiarowa w określonych warunkach temperaturowych i wilgotnościowych | DS(70,90) | % | ≤ 1 | EN 1604 |
| Naprężenie ściskające przy 10% odkształceniu | CS(10) | kPa | ≥ 0,5 | EN 826 |
| Wytrzymałość na rozciąganie prostopadłe do powierzchni czołowych | TR | kPa | NPD | EN 1607 |
| Obciążenie punktowe dla odkształcenia 5 mm | PL(5) | N | NPD | EN 12430 |
| Opór przepływu powietrza | AFr | kPa·s/m2 | 5 | EN 9053-1 |
| Krótkotrwała nasiąkliwość wodą | WS | kg/m2 | ≤ 1 | EN 29767 |
| Długotrwała nasiąkliwość wodą przy częściowym zanurzeniu | WL(P) | kg/m2 | ≤ 3 | EN 16535 |
| Współczynnik oporu dyfuzyjnego pary wodnej | MU | - | MU1 | EN 13162+A1 |
| Reakcja na ogień | RtF | - | A1 | EN 13501-1, EN 15715 |
NPD - No Performance Declared
DEKLAROWANY OPÓR CIEPLNY
Wartości deklarowanego oporu cieplnego RD | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Grubość [mm] | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 | 110 | 120 | 130 | 140 | 150 |
| RD [m²K/W] | - | - | - | - | 1,35 | 1,65 | 1,95 | 2,20 | 2,50 | 2,80 | 3,05 | 3,35 | 3,65 | 3,95 | 4,20 |
| Grubość [mm] | 160 | 170 | 180 | 190 | 200 | 210 | 220 | 230 | 240 | 250 | 260 | 270 | 280 | 290 | 300 |
| RD [m²K/W] | 4,50 | 4,80 | 5,05 | 5,35 | 5,65 | 5,95 | 6,20 | 6,50 | 6,80 | 7,05 | 7,35 | 7,65 | 7,95 | 8,20 | 8,50 |
PRODUCT FEATURES
Dimensions:
- Board format: 1200 x 600 mm
- Thickness range: 50 - 300 mm
Logistics, packaging, storage
- Packaging on PILLAR bases or wooden pallets
- Possibility of packaging on high H2.6 pallets (double product quantity)
- Full truck load: 22 standard pallets / 11 high pallets marked H2.6
- The product can be stored outdoors in its original packaging on a stable and dry surface.
- Maximum stacking height: 3 meters
Documentation
- Declaration of performance: Nr HP/GB/HL/2025_07
- Certificate number: 1454-CPR - 0292
- Marking code: MW-EN 13162-T2-DS(70,90)-CS(10)0,5-AFr5-WS-WL(P)-MU1